C3 User Guide
80
Mechanical engine monitoring and shutdown
Description
A combination of a C3 digital input and output can provide a simple method to
add after-market monitoring and shutdown control of an engine. Leveraging the
FYJTUJOHTIVUEPXOQSPUFDUJPOPGBOFOHJOFUIFTUBUFPGUIFJOQVUSFçFDUTUIFTUBUF
of the engine. A normally closed relay contact can be used to shutdown the engine
remotely.
Electrical connection
The power connection to the fuel solenoid or ignition of the engine
can be wired directly to a C3 input (tolerant of 24 V systems)
The existing engine protection system will cut power to this connection if
an engine over-temperature or oil under-pressure condition is present
A generic automotive relay can be wired in-line with the solenoid
QPXFSDPOOFDUJPOUIF$DBOUIFOCFDPOæHVSFEUPIPMEUIJTSFMBZ
on for a short period of time to shut the engine down (Figure 39)
Installation notes
The automotive relay is best connected as close as possible to the fuel
solenoid/ignition connection
The relay would typically be housed within the existing engine protection
system enclosure