X-MDA-1™ User Manual Installation and X-320M™ Setup
2.11 UV Sensor
Sensor Connection: Analog 3
Slope: 6.4
Offset: 0
Units: UV index
2.12 Barometric Pressure
The following settings are for the Apogee Instruments SB-110. See Section 3 for additional information.
Sensor Connection: (The user may connect this sensor to any available analog port. Please refer to
the user manual.)
Slope: 6.437
Offset: 3.637
Adjustment: Sea Level
Units: inHg
2.13 Soil Moisture
The following settings are for the Irrometer Soil Moisture Sensor. See Section 3 for additional
information.
Sensor Connection: (The user may connect this sensor to any available analog port. Please refer to
the user manual.)
Slope: 85.35714
Offset: 0.00
Units: cb
A soil moisture levels above 239 are error indications. 247.53 (2.9 V) indicates frozen sensor. 256.07
(3.0V) indicates an open circuit. Refer to Watermark documentation for more information. Please keep in
mind that the slope value may affect the error codes and direct probing of the voltage values or
temporarily setting the slope to 1 may be required to verify the error state.
Xytronix Research & Design, Inc. Page 15